EGOSILICON 460 BAUFIX

Silicone sealant for building waterproofing

EGOSILICON 460 BAUFIX is a ready-to-use 1K silicone sealant that cures to an elastic and flexible end product through reaction with humidity. This product is ideal for sealing connection and expansion joints and demonstrates excellent adhesion to various materials such as concrete, masonry, glass, tiles, ceramics, metals, coated wood, and many stress-free plastics.

  • abrasion-resistant
  • complies with DIN18540
  • fungicide
  • neutral cross-linking (alkoxy)
  • odorless
  • paint-compatible
  • weather, ageing & UV-resistant

EGOSILICON 460 BAUFIX offers a reliable and durable solution for a wide range of sealing projects both indoors and outdoors

Areas of application

  • Concrete,
  • Roof,
  • Enamel,
  • Fibre cement,
  • Facades,
  • Windows,
  • Tiles,
  • Glass,
  • Glass sealing,
  • Timber,
  • Ceramics,
  • Air conditioning & heating,
  • Clinker,
  • Artificial stone,
  • Plastics,
  • Copper [with primer],
  • Ventilation,
  • Marine,
  • Masonry,
  • Metal,
  • Masonry,
  • Plaster,
  • HVAC systems,
  • Clean room,
  • Sanitary
PDF
net per [RRP ]
Please note minimum quantity

Total price (net)

Availability

Log in

  • 1C system
    1C system
  • 100 % free of solvents
    100 % free of solvents
  • Fungicidal (prevents fungal growth)
    Fungicidal (prevents fungal growth)
  • Neutral curing
    Neutral curing
  • Odorless
    Odorless
  • UV, ageing, weather resistance
    UV, ageing, weather resistance
  • baubook
    baubook
  • CE  marking
    CE marking
  • ift-guideline  Formation of streaks / abrasion
    ift-guideline Formation of streaks / abrasion
  • LEED  EQ c4.1
    LEED EQ c4.1
  • Clean room  VDI 2083
    Clean room VDI 2083
  • Clean air technology  VDI 6022
    Clean air technology VDI 6022
  • Kömmerling Testing in accordance with ift guideline DI 01/1 Usability of sealants Part 1
Testing of materials in contact with the insulating glass edge seal, test method: Triple test P1, Chapter 4.1 GD 115
    Kömmerling | GD 115 (May 2010)
  • Fenzi Testing in accordance with ift guideline DI 01/1 Usability of sealants Part 1
Testing of materials in contact with the insulating glass edge seal, test method: Triple test P1, Chapter 4.1 Thiover
    Fenzi | Thiover (March 2017)
  • IGK Isolierglasklebstoffe Testing in accordance with ift guideline DI 01/1 Usability of sealants Part 1
Testing of materials in contact with the insulating glass edge seal, test method: Triple test P1, Chapter 4.1 IGK 511 / IGK 311
    IGK Isolierglasklebstoffe | IGK 511 / IGK 311 (April 2024)
  • IGK Isolierglasklebstoffe Testing in accordance with ift guideline DI 01/1 Usability of sealants Part 1
Testing of materials in contact with the insulating glass edge seal, test method: Triple test P1, Chapter 4.1 IGK 511 / IGK 330
    IGK Isolierglasklebstoffe | IGK 511 / IGK 330 (April 2024)
  • IGK Isolierglasklebstoffe Testing in accordance with ift guideline DI 01/1 Usability of sealants Part 1
Testing of materials in contact with the insulating glass edge seal, test method: Triple test P1, Chapter 4.1 IGK 511 / IGK 130
    IGK Isolierglasklebstoffe | IGK 511 / IGK 130 (April 2024)
  • Fenzi Test method: on multi-pane insulating glass with test material in contact (MIG test) P3, Chapter 4.3 Butylver/Poliver
    Fenzi | Butylver/Poliver (March 2017)
  • Dow Corning Test method: on multi-pane insulating glass with test material in contact (MIG test) P3, Chapter 4.3 DC 3363
    Dow Corning | DC 3363 (November 2018)
  • Dow Corning Test method: on multi-pane insulating glass with test material in contact (MIG test) P3, Chapter 4.3 DC 3362
    Dow Corning | DC 3362 (May 2012)
  • Kömmerling Test method: on multi-pane insulating glass with test material in contact (MIG test) P3, Chapter 4.3 GD 677
    Kömmerling | GD 677 (April 2015)
  • Kömmerling Test method: on multi-pane insulating glass with test material in contact (MIG test) P3, Chapter 4.3 GD 677 NA
    Kömmerling | GD 677 NA (April 2015)
  • Solutia/Eastman Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Saflex IIIG
    Solutia/Eastman | Saflex IIIG (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trosifol BG R15
    Kuraray | Trosifol BG R15 (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trosifol BG R20
    Kuraray | Trosifol BG R20 (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trosifol ES
    Kuraray | Trosifol ES (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trosifol SC
    Kuraray | Trosifol SC (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trosifol SC+
    Kuraray | Trosifol SC+ (May 2016)
  • Kuraray Testing in accordance with ift guideline DI 02/1 Suitability of sealants
Part 2: Testing of materials in contact with the edge of laminated and laminated safety glass Trofisol HR 100
    Kuraray | Trofisol HR 100 (October 2010)

The above assessment is based on laboratory tests carried out on samples provided to us and on EGO's practical experience. However, as not all processing and application-related parameters are known, the results do not constitute a guaranteed property. In order to reliably evaluate the interaction of complex systems under production and application conditions, tests by the respective manufacturer or processor are necessary. EGO cannot accept any responsibility for interim changes to the product formulations of primary and secondary sealants and laminated safety glass films. It is therefore recommended that you consult the manufacturer of the tested samples.